Model 7000 Series Turbine Flowmeter Section 1
Shielded wire cable conveys the output of the pickup coil to compatible elec-
tronic instruments to indicate ow rate, record, and/or totalize the volumet-
ric ow. Since the coil itself does not require electrical power, the standard
pickup coil incorporates connection pins that mate to a quick connector.
The pickup coil can drive a variety of instruments including ow rate indica-
tors, totalizers, preampliers or ow computers/RTUs. Preampliers are used
to transmit the coil signal over extended distances to remote-mounted instru-
ments.
The meter may be factory-tted with multiple coils for redundancy, indication
of ow direction or pulse train verication.
The pickup coil type and magnetic strength vary with application require-
ments. For coil replacement, refer to the part number etched on the coil body.
Specications—Standard Pickup Coil
Temperature Range ........................ -450°F to +450°F (-268°C to +232°C) (not including
meter and mating connectors)
DC Resistance................................ 1200 ohms (nominal)
Inductance ...................................... 450 mh (nominal)
Dielectric Strength Rating ............... 500 VAC rms minimum
Insulation Resistance Rating .......... 100 megaohms @100V
Number of Pins ............................... 2
Connector ....................................... MIL-C-5015 (mates with MS31 06-10SL-4S)
Dimensions ..................................... See Section 5 - ODD Drawing
Other models may be suitable, depending on the application. See the Spare
Parts List, page 18, for information on alternate models.
CEMarkings(forPEDowmetersonly)
Barton 7000 owmeters that are built to conform to the European Union Pres-
surized Equipment Directive (PED) are marked with the following:
• Part number
• Serial number
• Maximum working pressure
• Minimum working pressure
• Minimum temperature (°F, °C)
• Nominal diameter
• Material
• Manufacturer's name and address
• CE mark*
• Notied body identication number
*1-in. owmeters are not CE-marked. The basis for PED conformance is
Sound Engineering Practice (SEP).