8
Section 2 Model 7000 Series Turbine Flowmeter
!
WARNING:
Thecustomerisresponsibleforensuringchemicalcompatibilitybetween
theowmeterandanyuidsbeingmetered.
Neverexceedthemaximumrecommendedpressureandtemperature
limits.
Neverexceedthemaximumrecommendedowrateforthemeter.
Forinstallationswherethepressurecouldexceedtheratedmaximum
safeworkingpressureoftheturbinemeterhousingoranges,thepiping
systemmustincludeprotectivemeasurestopreventoverpressure,in
accordancewithapplicablelocalandnationalpipingcode.
Theturbinemeterisnotdesignedforhighstaticordynamicloadsatthe
endconnections.Thepipingsystemmustbedesignedwithadequate
supportstominimizetheloadsattheturbinemeter,inaccordancewith
applicablelocalandnationalpipingcode.
Theturbinemetermaybeunderpressure.Ensurethatthepipingsystem
iscompletelydepressurizedbeforeremovingthemeterformaintenance
orinspection.