Dok.-Nr.: D10029.EN Rev.: 11 Page 17 of 30
Manual: Water separator / Fuel pre-filter SWK-2000
Willibrord Lösing
Filterproduktion GmbH
W. Lösing Filterproduktion GmbH • Am Walzwerk 2 • 45527 Hattingen
5.2 Double-unit system
In the case of a double-unit system, two identical filters are installed parallel in the fuel circulation.
By parallelising the filter, the double-unit system is able to achieve twice the flow rate as that of a
single filter.
Example of a double-unit filter system
4
:
Deviations to Chapter 4.2 Dimensions and weights
SWK-2000/40/2
SWK-2000/130/2
Width [mm]
870
1.100
Height [mm]
480
860
Depth [mm]
240
370
Weight [kg]
< 35
< 120
Fixing holes [mm]
4x slotted
holes (24x12)
Distance apart: 835x100
16x slotted holes (27x15)
Distance apart:
See drawings
All sizes and weights may vary according to the precise configuration of the filter assembly. The
exact dimensions should be taken from the specific drawing of your filter.
4
Example includes special options
The standard
inlets and
outlets remain
closed
Fuel inlet
Fuel outlet