5 Active location: lines
Note:
●
If a frequency of less than 8 kHz or greater than 10 kHz is
selected during measuring mode, the function is switched off
automatically. If a frequency between 8 kHz and 10 kHz is then
subsequently selected, the function is automatically switched
back on.
●
Direction recognition is not available on the receiver if the High
Power function is enabled on the generator.
5.5 High Power
The UT 9012 TX generator has a maximum output power of
12 W. In order to reduce power consumption, in normal measur-
ing mode its highest power level is 7 W. The High Power function
is used to set the generator to energise with an output power of
12Wforaspeciedtime.
Note:
The High Power function is not available on the UT 9005 TX
generator.
This function is particularly useful for locating across large dis-
tances.
This function is only available for:
● operating mode: Galvanic energising
● frequencies below 10 kHz