EasyManua.ls Logo

sewerin UT 9000 - 8.2 Problems with the receiver

Default Icon
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69
8 Troubleshooting
Users who primarily use acoustic location can sometimes locate
actitiouslineCbetweenlineAandlineB.
It is possible to avoid this error by checking carefully the direc-
tional arrows on the display. The directional arrows show the
direction in which a line is located. Directly over a line the direc-
tional arrows turn into a diamond. As C is not a line, no diamond
appears.
8.2 Problems with the receiver
Problem Possible cause Corrective action
Cannot switch on
receiver
Remaining battery
capacity too low
● Change the batteries
● Charge the batteries
Power supply
interrupted
● Check battery contact
Receiver does
not respond when
switched on
Receiver faulty ● Remove and replace the
batteries > attempt to
switch receiver on once
more
Remaining battery
capacity too low
● Change the batteries
No acoustic signal
audible
Tone switched off or
volume setting too
low
● Increase volume
Display shows un-
usuallyuctuating
values
Interferenceelds
present
● Eliminate interference
elds:e.g.switchoffcom-
puters, monitors, light
dimmers, industrial appli-
ances
Active location:
Field strength over-
loaded (with mini-
mum gain)
Receiver too close to
generator
● Move receiver away from
generator