SI 480E DIN SIZE WEIGHING CONTROLER
Serial Communication Speed selection
F31
0
2,400bps
1
4,800bps
2
9,600bps
3
14,400bps
4
19,200bps
5
28,800bps
6
38,400bps
7
57,600bps
8
76,800bps
9
115,200bps
DATA Transference Method selection
F32
0
Simplex Mode / Stream Mode
1
Duplex Mode / Command Mode
2
Print Mode
“Check-Sum” detection selection (Under F32-01 setting, only)
F34
0
Check-Sum Not Use
1
Check-Sum Use
Under Stream Mode select the way transmit data protocol/frame (basic port)
F35
0
Transmit by Protocol
1
Transmit by frame (in case of using specific utility)
Caution : In case of Transmit by frame & under 14,400bps setting(F31), the speed of
system will be slow.
DATA Transference Mode selection (Under F32-00 setting, only)
F36
0
Always
1
Single time data transference, Whenever the weight is steady over Empty
range.
2
Single time data transference, at first steady point, over Empty range.
3
Data transference, Whenever “Print” key input
DATA Transference Format selection (Under F32-00 setting, only)
F37
0
Format 1 (recommended when use external display)
1
Format 2. (Format 1 + ID No.)