13. Display P4 
 4P yalpsiD motpmys melborP
 noitcetorp erutarepmetrevo egrahcsiD esuaC
 noitcA sisongaid fo tnetnoC .oN noitcnuflaM
1  Check if the air inlet and outlet of outdoor unit is blocked by any 
obstructions. 
Install to the position as required in the Instruction 
Manual and ensure the air inlet and outlet of the 
outdoor unit is smooth. 
 tnaregirfer ddA .tnaregirfer fo egatrohs rof metsys eht kcehC 2
3  Check if the exhaust temperature sensor is drifted, short circuited or 
open circuited. (25ć/20k). For other resistances, please refer to 
the Exhaust Temperature Sensor – Resistance Sheet) 
Replace the exhaust temperature sensor 
 draob ecruos rewop roodtuo eht ecalpeR degamad draob lortnoC 4
 
 
 
14. Display P2 
 2P yalpsiD motpmys melborP
 noitcetorp tnerrucrevO esuaC
 noitcA sisongaid fo tnetnoC .oN noitcnuflaM
1 Check if the outdoor fan motor is stopped due to overheat 
protection, or damaged, and if the fan capacitor is damaged. 
Replace the fan capacitor,replace the outdoor power  
source board and the damaged outdoor fan motor. 
15. Display P5 
 5P yalpsiD motpmys melborP
 edom gnilooc rednu noitcetorp gniloocbuS esuaC
 noitcA sisongaid fo tnetnoC .oN noitcnuflaM
1  Check if the air inlet and outlet of indoor unit is blocked by any 
obstructions. 
Install to the position as required in the Installation manual 
and ensure the air inlet and outlet of the outdoor unit is 
smooth. 
2  Check the system for shortage of refrigerant.  Add refrigerant 
3  Check if the exhaust temperature sensor is drifted, short 
circuited or open circuited. (Measure the resistance of the 
resistors on two ends of indoor temperature sensor: (25ć / 
5k). For other resistances, please refer to the Temperature – 
Resistance Sheet. 
Replace room temperature sensor (IRT) and Indoor pipe 
(coil) temperature sensor (IPT) 
 draob lortnoc roodni eht ecalpeR degamad draob lortnoC 4
16. Display P6 
 6P yalpsiD motpmys melborP
cetorp gnitaehrevO esuaC tion under cooling mode 
 noitcA sisongaid fo tnetnoC .oN noitcnuflaM
1  Check if the air inlet and outlet of outdoor unit is blocked by any 
obstructions. 
Install to the position as required in the Installation manual 
and ensure the air inlet and outlet of the outdoor unit is 
smooth. 
2  Check the system for shortage of refrigerant.  Add refrigerant 
3  Check if the outdoor evaporator coil temperature sensor is 
drifted, short circuited or open circuited (25 /5K). For other ć
resistance, please refer to the Temperature – Resistance 
Sheet. 
Replace the outdoor coil temperature sensor 
 draob ecruos rewop roodtuo eht ecalpeR degamad draob lortnoC 4
3-17