Procedure LCD Operation
30 <signal type>
SELECT SPEED
31 Press or to select the target speed. <signal speed>
PRESS ENTER KEY
For <signal speed>, refer to TABLE-4.
32 When the target speed is displayed, press ENTER. <signal speed>
SELECT DATA
33 Press or to select the target data to be sent. <data>
PRESS ENTER KEY
For <data>, refer to TABLE-5.
34 When the target data is displayed, press ENTER. <signal speed>
<data>
The selected signal is sent.
35 Press STOP. <signal speed>
SELECT DATA
Signal send stop
36 (To change data only)
Go to 33.
(To change speed)
Press STOP.
<signal type>
SELECT SPEED
(To change the signal kind)
Press STOP twice.
04:SIGNAL SEND
SELECT SIGNAL
(To terminate this mode)
Press STOP 3 times.
This mode is terminated.
40 7:TONE
SELECT FREQUENCY
41 Press or to select the target frequency. <signal freq.>
PRESS ENTER KEY
For <signal freq.>, refer to TABLE-4.
42 When the target frequency is displayed, press
ENTER.
<signal freq.> The selected signal is sent.
43 Press STOP. 7:TONE
SELECT FREQUENCY
Signal send stop
44 (To change the frequency only)
Go to 41.
(To change the signal kind)
Press STOP.
04:SIGNAL SEND
SELECT SIGNAL
(To terminate this mode)
Press STOP twice.
This mode is terminated.
TABLE-3: Signals in the Signal send mode
MODE # MENU DISPLAY
1 No signal 1:NO SIGNAL
2 DTMF 2:DTMF
3 V.17 3:V.17
4 V.29 4:V.29
5 V27ter 5:V27ter
6 FLAG 6:FLAG
7 Tone (CED/CNG) 7:TONE
TABLE-4: Speed/Frequency in the Signal send mode
MODE # MENU ITEM 1 MENU ITEM 2 MENU ITEM 3 MENU ITEM 4
3 1:V.17 14400BPS 2:V.17 12000BPS 3:V.17 9600BPS 4:V.17 7200BPS
4 1:V.29 9600BPS 2:V.29 7200BPS
5 1:V27ter 4800BPS 2:V27ter 2400BPS
6 1:FLAG 300BPS
7 1:TONE 2100Hz 2:TONE 1100Hz
AR-F152