EasyManua.ls Logo

Sharp AR-151 - Page 107

Sharp AR-151
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TABLE-5: Data which is sent in the Signal send mode
MODE # MENU (DATA) DISPLAY
1 00000000b 1:00000000b
2 11111111b 2:11111111b
3 01010101b 3:01010101b
(5) Image memory clear mode
Procedure LCD Operation
1 Press FUNCTION, 9, , 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU( )
3 Press 1, 0. 10:IMAGE MEM CLEAR
1:OK 2:CANCEL
4 Press 1. DIAGNOSTIC MODE
SELECT MENU( )
The image data are cleared and this mode is
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure LCD Operation
1 Press FUNCTION, 9, , 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU( )
3 Press 1, 4. 14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4 Press or .
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press to decrease by 1%.
Press to increase by 1%.
5 Press ENTER. “1590” is dialed.
6 (Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure LCD Operation
1 Press FUNCTION, 9, , 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU( )
3 Press 1, 6. 16:DIAL TEST TONE “1234567890#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure LCD Operation
1 Press FUNCTION, 9, , 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU( )
3 Press 2, 1. 21:PRINT SOFT SW The soft switch list is printed.
This mode is terminated.