TABLE-5: Data which is sent in the Signal send mode
MODE # MENU (DATA) DISPLAY
1 00000000b 1:00000000b
2 11111111b 2:11111111b
3 01010101b 3:01010101b
(5) Image memory clear mode
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 1, 0. 10:IMAGE MEM CLEAR
1:OK 2:CANCEL
4 Press 1. DIAGNOSTIC MODE
SELECT MENU(← →)
The image data are cleared and this mode is
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 1, 4. 14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4 Press ← or →.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press ← to decrease by 1%.
Press → to increase by 1%.
5 Press ENTER. “1590” is dialed.
6 (Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 1, 6. 16:DIAL TEST TONE “123456789∗0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 2, 1. 21:PRINT SOFT SW The soft switch list is printed.
This mode is terminated.
AR-F152