(9) Panel check mode
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 4, 2. 42:FAX PANEL TEST
4 Press any key. 42:FAX PANEL TEST
<key name>
The name of the pressed key is displayed in the
lower stage of the LCD.
5 Press STOP. This mode is terminated.
(10) Signal detect mode
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 4, 3. 43:SIG. DETECT
4 (When DTMF signal is detected) 43:SIG. DETECT
DTMF:<number>
(When CNG signal is detected) 43:SIG. DETECT
CNG
(When QUIET signal is detected) 43:SIG. DETECT
QUIET
(To terminate this mode)
Press STOP.
This mode is terminated.
(11) Long distance comm select mode
Procedure LCD Operation
1 Press FUNCTION, 9, ∗, 8, #, 7. DIAGNOSTIC MODE
ROM VERSION =
<version>
2 Press ENTER. DIAGNOSTIC MODE
SELECT MENU(← →)
3 Press 4, 4. 44:LONG DIST COMM
1:SET 2:CLEAR
To terminate this mode, press STOP.
4 Select the mode. To register → 10
To cancel registration → 20
10 Press 1. SET
ENTER # OR RAPID
11 Press the desired one touch key or the speed
dial (2 digits) to be registered.
SELECT SPEED
1:9600BPS 2:4800BPS
12 Select the speed. (Press 1 or 2.) <Name or Number>
STORED
13 Return to 3.
20 Press 2. CLEAR
ENTER # OR RAPID
21 Press the desired one-touch key or speed dial (2
digits) to be canceled.
<Name or Number>
CLEARED
22 Return to 3.
Note:
● One-touch keys and speed dials which are not registered cannot be designated.
● When one-touch keys and speed dials which are registered are canceled, this setup is also canceled.
● The group key and the polling key cannot be designated.
AR-F152
9 – 19