SW
No.
Bit
No.
ITEM Soft SW setting and function Factory Setting
8 5 EOL detection timer Used to set the EOL (End of Life) detection time to 25sec or
13sec. This function is effective to avoid a communication
error due to long EOL of certain models.
0
6 Reserved 0
7 Reserved 0
8 ECM Used to set ON/OFF of ECM. 1
91
2
Interval between OFF-HOOK and
dial send
Used to set the delay from OFF-HOOK when starting dialing
to actual send start of the dial signal.
If the dial tone detection function is enabled, this setup is
ignored.
1
1
3 Reserved 0
4 Reserved 0
5
6
Reserved 0
0
7
8
Reserved 0
0
10 1 Reserved 0
2 FAST Used to set Enable/Disable of RMS (FAST) function. 0
3 Reserved 1
4 Basic resolution Used to select the basic resolution for scanning and printing. 0
5 Reserved 0
6
7
8
Language Used to select the language displayed on the LCD and the
report. The correspondence between language N and the
actual language differs depending on the destination.
0
0
0
1 : 25 sec 0 : 13 sec
1 : ON 0 : OFF
Bit No. 0.5sec 1sec 2sec 3sec
10011
20101
1 : Enable 0 : Disable
1 : Inch series 0 : Metric series
Language 1 Language 2 Language 3
For North
America
American
English
French Spanish
Bit
No.
Lan-
guage
1
Lan-
guage
2
Lan-
guage
3
Reserved
600001111
700110011
801010101
AR-F152
9 – 23