Before calling for repair, please review the list below, since the problem may not be a unit malfunction
.
TROUBLESHOOTING
SPECIFICATIONS
Power supply 220-240V 50/60Hz
Fan
Speed
Operation
Fan Speed Adjustment MAX MED LOW
Rated Power 48W 27W 12W
Fan Speed 168m
3
/hour 108m
3
/hour 48m
3
/hour
Recommended Room Size ~19m
2
*1
High density Plasmacluster ion recommended room size
~16m
2
*2
Cord Length 2.0m
Dimensions 385mm(W)x128mm(D)x380mm(H)
Weight
3.4kg
*1 Size of a room which is appropriate for operating the unit at maximum fan speed.
• It indicates the space where a certain amount of dust particles can be removed in 30
minutes(JEM1467).
*2 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the floor) when the product is
placed next to a wall and run at the MAX operation position.
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 1.0W of standby power.
For energy saving, unplug the power cord when the unit is not in use.
SYMPTOM REMEDY (not a malfunction)
Dust and smoke are not removed.
•Clean or replace the filter if they appear to be heavily
soiled.(Refer to E-6,E-7
)
A clicking or ticking sound is heard
from the unit.
• Clicking or ticking sound may be audible when the unit
is generating ions.
The discharged air has an odour.
•Check to see if the filter are heavily soiled.
Replace the filter.
•Plasmacluster Air Purifiers emit small traces of ozone
which may produce an odour. These ozone emissions
are well below safety levels.