LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
5 – 16
Point 2
LEV20048
MG2R0192
[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
MG2G0192 Level Reference value Adjustment spec Inspection spec
MG2B0192
Point 7 928
X=0.3127
±0.0010 ±0.0020
MG2Y0192
1G2G****
y=0.329
1G2B****
1G2R****
Point 6 784
X=0.3127
±0.0015 ±0.0030
1G2Y**** y=0.329
Point 1
Point 5 624
X=0.3127
±0.0020 ±0.0040
LEV10020 y=0.329
MG1G0000
Point 4 432
X=0.3127
±0.0030 ±0.0060
MG1B0000 y=0.329
MG1R0000
Point 3 304
X=0.3127
±0.0035 ±0.0070
MG1Y0000 y=0.329
1G1G****
Point 2 192
X=0.3127
±0.0040 ±0.0080
1G1B**** y=0.329
1G1R****
1G1Y****
The MAX brightness mea-
sured after adjustment
CHGM1255
Remarks Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Writing
MSET0030
Brightness specification after adjustment.
LC-60/70UQ17U:Min 368cd/m2
LC-80UQ17U:Min 328cd/m2
Adjustment
point
Adjustment conditions Adjustment procedure