MX-5001N SIMULATION 6 – 55
* Item L: 1 Count = 1s Change
Correction value for the other items: 1 count for 1°C change
N HL_LM HEAVY HH Correction value for heavy paper TH_LM set value under
HH environment
1 - 99 50 50 50 –
O HL_E HEAVY HH Correction value for heavy paper TH_E set value under HH
environment
1 - 99 50 50 50 –
P HL_UM OHP HH Correction value for OHP TH_UM set value under HH
environment
1 - 99 50 50 50 –
Q HL_LM OHP HH Correction value for OHP TH_LM set value under HH
environment
1 - 99 50 50 50 –
R HL_E OHP HH Correction value for OHP TH_E set value under HH
environment
1 - 99 50 50 50 –
S HL_UM ENVELOPE HH Correction value for envelope TH_UM set value under HH
environment
1 - 99 50 50 50 –
T HL_LM ENVELOPE HH Correction value for envelope TH_LM set value under HH
environment
1 - 99 50 50 50 –
U HL_E ENVELOPE HH Correction value for envelope TH_E set value under HH
environment
1 - 99 50 50 50 –
V HL_UM GLOSS HH Correction value for glossy paper TH_UM set value under
HH environment
1 - 99 50 50 50 –
W HL_LM GLOSS HH Correction value for glossy paper TH_LM set value under
HH environment
1 - 99 50 50 50 –
X HL_E GLOSS HH Correction value for glossy paper TH_E set value under HH
environment
1 - 99 50 50 50 –
Y HL_UM E-STAR HH Correction value for preheating TH_UM set value under HH
environment
1 - 99 50 50 50 –
Z HL_E E-STAR HH Correction value for preheating TH_E set value under HH
environment
1 - 99 50 50 50 –
AA PRE-JOB HH Correction value for resetting from preheating
TH_UM+TH_E set value under HH environment
1 - 99 50 50 50 –
AB HL_LM E-STAR HH Correction value for preheating TH_LM set value under HH
environment
1 - 99 50 50 50 –
AC HL UM HEAVY2 CL HH Correction value for heavy paper 2 TH_UM set value under
HH environment
1 - 99 50 50 50 –
AD HL LM HEAVY2 CL HH Correction value for heavy paper 2 TH_LM set value under
HH environment
1 - 99 50 50 50 –
AE HL E HEAVY2 CL HH Correction value for heavy paper 2 TH_E set value under
HH environment
1 - 99 50 50 50 –
AF HL_UM WARMUP_120L HH Correction value for TH_UM set value in WarmUp at 120°C
or below under HH environment
1 - 99 50 50 50 –
AG HL_LM WARMUP_120L HH Correction value for TH_LM set value in WarmUp at 120°C
or below under HH environment
1 - 99 50 50 50 –
AH HL_E WARMUP_120L HH Correction value for TH_E set value in WarmUp at 120°C or
below under HH environment
1 - 99 50 50 50 –
AI LO_WARMUP_TIME_HH Correction value for AF-AH applying time (timer from Ready
complete) under HH environment
1 - 99 50 50 50 –
AJ HL_UM WARMUP_120H HH Correction value for TH_UM set value in WarmUp at 120°C
or above under HH environment
1 - 99 50 50 50 –
AK HL_LM WARMUP_120H HH Correction value for TH_LM set value in WarmUp at 120°C
or above under HH environment
1 - 99 50 50 50 –
AL HL_E WARMUP_120H HH Correction value for TH_E set value in WarmUp at 120°C or
above under HH environment
1 - 99 50 50 50 –
AM HI_WU_TIME_HH Correction value for AJ-AL applying time (timer from Ready
complete) under HH environment
1 - 99 50 50 50 –
AN HI_WU_FM_ON_TMP_HH Correction value for FM prior rotation start TH_E in
WarmUp at alpha °C or above under HH environment
1 - 99 50 50 50 –
AO HI_WU_END_TIME_HH Correction value for WarmUp completion time in WarmUp
at alpha °C or above under HH environment
1 - 99 50 50 50 –
AP HI_WU_JOB_SET_TMP_HH Correction value for Job Enable TH_UM temperature in
WarmUp at alpha °C or above under HH environment
1 - 99 50 50 50 –
AQ HI_WARMUP_BORDER_HH Correction value for the threshold value alpha applying
SIM43-1-AN - AP under HH environment
1 - 99 50 50 50 –
AR LO_WU_JOB_SET_TMP_HH Correction value for Job Enable TH_UM temperature in
WarmUp at alpha °C or below under HH environment
1 - 99 50 50 50 –
AS ROT_TIME_AFTER_JOB_HH Correction value for the after rotation time when completing
a job under HH environment
1 - 99 50 50 50 –
Item/Display Content
Setting
range
Default value Destination
linkage
(NOTE)
Group 1 Group 2 Group 3