MX-C250 SIMULATION 6 – 33
44-9
Purpose
Operation data display
Function (Purpose)
Used to display the results data of the high
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
MODE
PAG
E
ITEM CONTETNT
DIS-
PLAY
RANGE
DEFA
ULT
VALU
E
PROCON
DATA
1/12
P DV K
High density pro-
cess control DV
data
0 - 600 450
P DV C (KCMY)
P DV M
P DV Y
2/12
P GB K
High density pro-
cess control GB
data
150 - 850 610
P GB C (KCMY)
P GB M
P GB Y
3/12
P DV K
BASE
High density pro-
cess control DV
data
0 - 600 450
P DV C
BASE
(KCMY) Target
P DV M
BASE
P DV Y
BASE
4/12
P GB K
BASE
High density pro-
cess control GB
data
150 - 850 630
P GB C
BASE
(KCMY) Target
P GB M
BASE
P GB Y
BASE
5/12
N(M)
DV K
High density pro-
cess control nor-
mal (medium speed
) DV data
0 - 600 450
N(M)
DV C
(KCMY)
N(M)
DV M
N(M)
DV Y
6/12
N(M)
GB K
High density pro-
cess control nor-
mal (medium speed
) GB data
150 - 850 630
N(M)
GB C
(KCMY)
N(M)
GB M
N(M)
GB Y
PROCON
DATA
7/12
N(M)
DV K
BASE
High density pro-
cess control nor-
mal (medium speed
) DV data
0 - 600 450
N(M)
DV C
BASE
(KCMY) Target
N(M)
DV M
BASE
N(M)
DV Y
BASE
8/12
N(M)
GB K
BASE
High density pro-
cess control nor-
mal (medium speed
) GB data
150 - 850 630
N(M)
GB C
BASE
(KCMY) Target
N(M)
GB M
BASE
N(M)
GB Y
BASE
9/12
N(L) DV
K
High density pro-
cess control nor-
mal(low speed ) DV
data
0 - 600
450
N(L) DV
C
(KCMY)
430
N(L) DV
M
N(L) DV
Y
10/12
N(L) GB
K
High density pro-
cess control nor-
mal(low speed ) DV
data
150 - 850
615
N(L) GB
C
(KCMY)
595
N(L) GB
M
N(L) GB
Y
11/12
N(L) DV
K BASE
High density pro-
cess control nor-
mal(low speed ) DV
data
0 - 600
450
N(L) DV
C BASE
(KCMY) Target
430
N(L) DV
M BASE
N(L) DV
Y BASE
12/12
N(L) GB
K BASE
High density pro-
cess control nor-
mal(low speed ) GB
data
150- 850
615
N(L) GB
C BASE
(KCMY) Target
595
N(L) GB
M BASE
N(L) GB
Y BASE
OTHER 1/21
TN HUD
AREA
Toner control dis-
play humidity area
1 - 14 8
TN HUD
DATA
Toner control dis-
play humidity AD
value
0 - 1023 0
TC TMP
AREA
Transfer display
temperature area
1 - 9 4
TC TMP
DATA
Transfer display
temperature AD
value
0 - 1023 0
MODE
PAG
E
ITEM CONTETNT
DIS-
PLAY
RANGE
DEFA
ULT
VALU
E

Table of Contents