MX-C250 SIMULATION 6 – 40
44-28
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
NOTE:
Set the items to the default values unless a change is spe-
cially required.
Mode Item/Display Content Setting range
Default
value
1
Process control
Enable/Disable
setting
INITIAL
YES When warm-up after clearing the
counter of the OPC drum and the
developer unit
Enable
0 - 1
0
0
NO Disable 1
2SW ON
When supplying the power (when
clearing shut-off.)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control
Enable
2
Pixel count judg-
ment (Judgement is
based on the setting
value of item K, L.)
3
3TIME
After passing the specified time from
leaving READY continuously (Time
can be changed by INTERVAL TIME)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control
Enable
2
Pixel count judg-
ment
(Judgement is
based on the setting
value of item K, L.)
3
4 HUM_LIMIT
HUM judgment is made when turning
ON the power and after passing
TIME.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control
Enable
2
5
Process control
Enable/Disable
setting
HUM
The temperature and humidity in side
the machine are monitored only dur-
ing a job for every 2hours (set by item
N). When the changes in the temper-
ature and the humidity are greater
than the specified level (the set value
of item O) in comparison with the pre-
vious process control.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control
Enable
2
6REV1
YES The accumulated traveling distance
of BK or M position OPC unit
reaches the specified level after turn-
ing the power.
Enable
0 - 1
0
0
NO Inhibit 1
7 REV2_BK
YES The accumulated traveling distance
of BK position OPC drum unit
reaches the specified level from exe-
cution of the previous density correc-
tion.
Enable
0 - 1
0
0
NO Inhibit 1
8 REV2_CL
YES The accumulated traveling distance
of M position OPC drum unit reaches
the specified level from execution of
the previous density correction.
Enable
0 - 1
0
0
NO Inhibit 1
9
REFRESH
MODE(*1)
YES
Select of YES/NO of the manual pro-
cess control key with key operation
Key operation dis-
play
0 - 1
0
1
NO
Key operation NO
display
1