MX-C250 SIMULATION 6 – 41
10
Process control
conditions set-
ting
DAY
When the next warm-up if there is no
color job after a color job after pass-
ing the specified days from execution
of the previous color process control
Disable of the speci-
fied days judgment
0 - 999
0
1
1 - 999 days passing 999
11 HI-COV
Setting of the execution judgment of the process control in
continuous printing of high print ratio images
0 - 1 0
12 LO-COV
Setting of the execution judgment of the process control in
continuous printing of low print ratio images
0 - 1 0
13 REV1_SH
When the accumulated traveling distance of K or M OPC
drum unit reaches the specified level after turning ON the
power.
0 - 1 1
14 REV2_BK_SH
When the accumulated traveling distance of K OPC drum
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1 1
15 REV2_CL_SH
When the accumulated traveling distance of M OPC drum
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1 1
16 AVERAGE-PAGE Setting of the number of pages of item HI-COV set value 2 1 - 10 3
17 LIMIT PAGE
Setting of the number of connected jobs of the process con-
trol and of the limit number of the process control
1 - 10 10
18 PIX_RATIO_BK
Variable magnification ratio setting (%) of the BK toner count
specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
1 - 999 10
19 PIX_RATIO_CL
Variable magnification ratio setting (%) of the color (CMY)
toner count specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
1 - 999 10
20 INTERVAL TIME
Setting of the leaving time when turning ON the power
(including the sleep recovery time) (h: hour)
1 - 255 3
21 HUM HOUR
Interval setting of the temperature and humidity monitoring
time of "HUM" (unit: 10 minutes)
1 - 24 2
22 HUM_DIF
The specified value of the area difference in humidity
between the level at execution of the previous control and the
current humidity (Applied to item HUM)
1 - 9 2
23 BK_RATIO
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV2_BK"
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
24 M_RATIO
Magnification ratio setting (%) of the M OPC drum traveling
distance of "REV2_CL"
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
25 REV1_RATIO
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV1"
1-999 20
26 REV1_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum
traveling distance of "REV1_SH”
1-999 20
27 BK_RATIO_SH
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV2_BK_SH"
1-999 15
28 M_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum
traveling distance of "REV2_CL_SH”
1-999 15
29 COLOR BORDER
Magnification ratio setting (%) of the
M position OPC drum traveling dis-
tance when executing the BK process
control
BK process control
is executed without
judgment of ratio of
the M OPC drum
traveling distance.
(Addition)
0 - 999
0
20
1 - 999(%)
1 -
999
30
BK ONLY
Disable/Enable setting and setting of
the number of repetition of the BK
process control when monochrome
print is continued.
Enable 5 time
0 - 6
0
4
Disable 1-5 times 1 - 5
Inhibit 6
31 HT_DIF
Bias change difference value used for judgment of HT pro-
cess control
1 - 255 40
32
Registration
adjustment set-
ting
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON pro-
cess control
0 - 2
0
0ALL 1
CL/BK 2
33 RG_TEMP_TIMER Execution timing setting after turning ON the power 0 - 240 (MINUTE) 0
34 RG_PERM_TIMER Span setting from execution Disable to Enable 0 - 15 (HOUR) 0
35
RG_HOUR_TIMER
Span setting of timer execution 0-15 (Above)+(MINUTE) 6
36
RG_BW_SYNC Setting of Enable/Disable of the registration adjustment after
a monochrome job
0-1 1
Mode Item/Display Content Setting range
Default