MX-C250 SIMULATION 6 – 67
66-32
Purpose
Operation test/Check
Function (Purpose)
Used to check the fixed data received from
the line and to display the result.
Section
FAX
Operation/Procedure
1) Press [OK]/[START] key to check the fixed data received from
the line.
* Fixed data check procedure
- The data received from the line is checked of the following
fixed data status for minutes, then if they are in accord with
"OK" is displayed on LCD, if not "NG" is displayed.
Receive speed: 300BPS
Receive data: 00H
Judgment data: 100byte
66-33
Purpose
Operation test/Check
Function (Purpose)
Used to execute detection of various sig-
nals with the line connected (CNG,CED,
BT, DT, DTMF) or line not connected (CI,
FNET) and to display the detection result.
When a signal is detected, the display is
highlighted.
Section
FAX
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Determine the setting values with [OK]/[START] key.
<Signal used for signal detection check>
(When "CI FNET" is selected)
(When "CNG/CED/BT/DT/DTMF" is selected)
66-34
Purpose
Operation test/Check
Function (Purpose)
Used to execute the send test and display
the time for sending (receiving) the image
data during sending the test data on LCD.
Section
FAX
Operation/Procedure
<Range>
Send : From sending the flag before sending the image data to
sending the RCP frame
Receive : From receiving the flag before receiving the image data
to receiving the RCP frame
1) Enter the SIM 66-34 mode.
2) Press [OK]/[START] key and the test is started. Then, the time
is displayed on LCD.
67
67-25
Purpose
Adjustment/Setup
Function (Purpose)
Printer color balance adjustment (Manual
adjustment)
Section
Printer
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Change the setting items with Arrow keys and determine the
setting values with [OK]/[START] key.
3) Set the adjustment value with 10 keys and save the value with
[OK]/[START] key.
When the adjustment value is increased, the image density is
increased, and vice versa.
67-31
Purpose
Data clear
Function (Purpose)
Used to clear the calibration value.
Section
Printer
Operation/Procedure
1) Press [OK]/[START] key.
The calibration data (Half tone correction data) are cleared.
(The color balance correction is canceled.)
67-33
Purpose
Adjustment/Setup
Function (Purpose)
Used to change the gamma of the printer
screen.
Section
Printer
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Change the setting items with Arrow keys and determine the
setting values with [OK]/[START] key.
3) Set the adjustment value with 10 keys and save the value with
[OK]/[START] key.
CI FNET
CNG CED BT DT DTMF
Item/Display Setting range Default value
1 POINT1 1 - 255 128
2 POINT2 1 - 255 128
3 POINT3 1 - 255 128
4 POINT4 1 - 255 128
5 POINT5 1 - 255 128
6 POINT6 1 - 255 128
7 POINT7 1 - 255 128
8 POINT8 1 - 255 128
9 POINT9 1 - 255 128
10 POINT10 1 - 255 128
11 POINT11 1 - 255 128
12 POINT12 1 - 255 128
13 POINT13 1 - 255 128
14 POINT14 1 - 255 128
15 POINT15 1 - 255 128
16 POINT16 1 - 255 128
17 POINT17 1 - 255 128
Item/Display Content
Set-
ting
Range
Heavy
paper or
screen1 to 7
Screen 8
Default
value
Default
value
1 POINT1 Point 1 0 - 255 128 127
2 POINT2 Point 2 0 - 255 128 125
3 POINT3 Point 3 0 - 255 128 124
4 POINT4 Point 4 0 - 255 128 124
5 POINT5 Point 5 0 - 255 128 122

Table of Contents

Other manuals for Sharp MX-C300F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp MX-C300F and is the answer not in the manual?

Sharp MX-C300F Specifications

General IconGeneral
BrandSharp
ModelMX-C300F
CategoryAll in One Printer
LanguageEnglish

Related product manuals