MX-FX11 FAX SOFTWARE SWITCH 2 – 2
8 1-5 Calling DTMF signal send time This sets the time that DTMF signals are sent when sending DTMF signals.
Send time can be set over the rage of 70 to 310ms in 10ms increments by
binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting range is set.
Adjustment value
6, 7 Calling Dial call waiting time This sets the waiting time from the end of line connection to the start of dial call
at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
Adjustment value
8 Calling Line current detection
at times of dial calling
Setting to determine whether or not to call dial following detection of line current
during line connection at times of automatic dial calling.
"1": No
"0": Yes
In cases where the setting is "Yes" but no line current can be detected, dial is
not called but the busy re-call procedure is followed.
Setting
9 1 Calling Manual calibration
setting when sending
Setting to execute the manual calibration or not when sending.
In case of an abnormal current waveform, the auto calibration fails and the
DTFM signal is deformed. This setting provides the countermeasure against
that problem.
"0": Execute
"1": Not execute
Setting
2 Call arrival Manual calibration
setting when a signal
arrives
Setting to execute the manual calibration or not when a signal arrives.
In case of an abnormal current waveform, the auto calibration fails and the
transmission is affected. This setting provides the countermeasure against that
problem.
"0": Execute
"1": Not execute
Setting
3-5 Not used
6 Calling No. 2 dial tone
detection
Setting of ON/OFF of No.2 dial tone detection function.
"0": OFF (No. 2 dial tone detection is not performed.)
"1": ON (No. 2 dial tone detection is performed.)
Setting
7 Calling Dial tone detection When the setting is "Yes," the dial is sent following confirmation of detection of
the dial tone when the line is captured; and when the setting is "No," dial is sent
without a dial tone because no confirmation of dial tone detection is carried out
after line capture.
"0": No
"1": Yes
Setting
8 Calling Dial tone ON detection
time (during
continuous detection)
This sets the waiting time from the end of line connection to the start of dial call
at times of automatic dial calling.
"0": 1.5 seconds
"1": 1 seconds
Adjustment value
10 1-4 Calling Lower limit of dial tone
ON/OFF detection time
(during intermittent
detection)
This sets the lower limit time for detection of dial tone ON/OFF time.
Setting can be made over the range of 40ms to 490ms in 30ms increments by
binary inputting.
(N x 30ms) + 40ms
This is only valid during intermittent DT detection.
Adjustment value
5-8 Calling Upper limit of dial tone
ON/OFF detection time
(during intermittent
detection)
This sets the upper limit time for detection of dial tone ON/OFF time.
Setting can be made over the range of 400ms to 1900ms in 100ms increments
by binary inputting.
(N x 100ms) + 400ms
This is only valid during intermittent DT detection.
Adjustment value
11 1-4 Calling External line
connection number
setting 1 <First digit>
When No. 2 dial tone is detected, this area is compared with the external in
connection number. If they match, the units waits for No. 2 dial tone.
Up to two external line connection numbers (max. 4 digits) can be registered as
options.
The first digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8 Calling External line
connection number
setting 1 <Second
digit>
The second digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
SW
No.
Bit
No.
Item SW selection and function System settings