MX-FX11 FAX SOFTWARE SWITCH 2 – 3
12 1-4 Calling External line
connection number
setting 1 <Third digit>
The third digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8 Calling External line
connection number
setting 1 <Fourth digit>
The fourth digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
13 1-4 Calling External line
connection number
setting 2 <First digit>
The first digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8 Calling External line
connection number
setting 2 <Second
digit>
The second digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
14 1-4 Calling External line
connection number
setting 2 <Third digit>
The third digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8 Calling External line
connection number
setting 2 <Fourth digit>
The fourth digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) /
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
15 1, 2 Calling DT/BT detection level This sets the minimum detection level for determining that dial tone and busy
tone have been detected. Signal levels not larger than this setting are ignored.
"00": -43dB
"01": -35dB
"10": -33dB
"11": -30dB
DT, BT common
Adjustment value
3, 4 Calling DT/BT detection
frequency range
setting
This sets the detection frequency range when detecting dial tone and busy
tone.
Change the setting if dial tone and busy tone are erroneously detected.
"00": MODEM fixed (about 308Hz - 517Hz)
"01": 420Hz - 680Hz
"10": 360Hz - 440Hz
"11": 245Hz - 650Hz
For CTR21: 245Hz - 650Hz
Adjustment value
5 Calling Busy tone detection Setting to determine whether or not to detect the busy tone signal during
automatic dial calling and when the external telephone simulated call sound is
ringing.
"0": Detect
"1": Do not detect
Setting
6 Calling Busy tone OFF non-
detection time
This sets the non-detection time on the busy tone OFF section.
Change the setting in cases where noise, etc. on the busy tone ON section
adversely affects the ON section.
"0": 100ms
"1": 300ms
* Make shorter than the "busy tone OFF detection time."
Adjustment value
7, 8 Calling Lower limit of busy
tone ON detection time
This sets the lower limit time of the ON section when detecting frequency of the
busy tone signal.
If busy tone signals are not detected in excess of this time, do not count as 1
pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
Adjustment value
SW
No.
Bit
No.
Item SW selection and function System settings