MX-M200D SIMULATIONS 7-48
65 10 Key reception time setting display/non-display setting
Used to set Enable/Disable of the key reception time setting in the system settings. When this setting is set
to Enable (1), the key reception time is displayed in the system settings, allowing setting.
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
1
11 Info lamp setting
Used to set the Info lamp brightness (PWM duty) and the kind of flashing.
During this simulation, Info lamp is lighted to allow checking of the brightness.
[CA] key: Exit the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Default:
Lamp brightness: 1
Kind of flashing: 1
67 50 USB reception speed adjustment
Used to set an limitation on the print data reception speed when the USB transfer speed is at full speed.
* When images are disturbed in printing through USB, change the setting and try again.
[CA] key: Exits from the simulation mode.
[INTERRUPT] key: Shifts to the sub code entry window.
Default:
3
Main
code
Sub
code
Contents Remark
Sim65-10 KEY TIME
1:KEY ACK TIME
[ 0- 1]
1
1
Display: Setting
0: Disable
1: Enable
Sim65-11 INFO LAMP
1:PWM DUTY
2:BLINK TYPE
[ 1- 5]
1
1
1
Lamp brightness
1: 100%
2: 80%
3: 60%
4: 40%
5: 20%
Kind of flashing
1: Flashing
2: Flashing 10 times, and lighting thereafter.
3: Lighting
Sim67-50 USB SPEED
1:FULL SPEED
2
2
Display : Setting
1 : FAST
2 : NORMAL 1
3 : NORMAL 2
4 : SAFE
[ 1- 4]
Slow
Fast