Parameter Reply Control/Response contents *
VOLUME VOLM WR 0-31 0-31
-
MUTE AUDIO MUTE WR 0-1 0-1 0: OFF, 1: ON
Temperature sensor DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Temperature acquisition ERRT R Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
-