Do you have a question about the Sharp SF-1020 and is the answer not in the manual?
| Printing Technology | Laser |
|---|---|
| Maximum Print Resolution | 600 x 600 dpi |
| Copier Type | Digital |
| Scan Type | Flatbed |
| Scan Resolution | 600 x 600 dpi |
| Paper Capacity | 250 sheets |
| Functions | Copier, fax, printer, scanner |
Step-by-step guide for correctly installing and setting the developing unit within the copier.
Explains how to adjust the toner density sensor level using simulation for accurate density control.
Step-by-step guide for installing the optional two-step paper feed unit (SF-CM15) onto the copier.
Instructions for installing the optional one-step paper feed unit (SF-CM16) onto the copier.
Details the image forming process step-by-step: Main Charging, Exposure, Development.
Details the process control for image density, including toner patch image formation and grid voltage.
Provides detailed instructions for disassembling and assembling the paper feed section, including the paper feed unit.
Covers the removal and replacement of components within the fusing section, such as the heater lamp and rollers.
Details procedures for replacing key components in the optical system, including the copy lamp and mirrors.
Instructions for cleaning and replacing components in the high voltage section, including the main charger unit.
Procedures for disassembling and cleaning parts of the process section, such as the process unit and waste toner bottle.
Details the adjustment procedures for the developing section, including doctor clearance and magnet roller position.
Lists the various optical system adjustment items, including lens reference position and magnification ratios.
Details specific adjustments for the optical system, including lens reference and No. 4/5 mirror position.
Step-by-step guide for adjusting the resolution and focus of the copier's optical system.
Procedure for adjusting vertical skew in copies caused by mirror base drive wire or mirror replacement.
Procedure for adjusting horizontal skew in copies, relevant after mirror base wire or mirror replacement.
Procedure for adjusting the center shift of the copy output if it deviates from the standard.
Procedure for adjusting exposure balance to ensure uniform exposure across the copy.
Adjustments for copy lead edge and void area to ensure proper copy size and reduce dirt.