Sharp SF-1020 - Copy Density Adjustment

Sharp SF-1020
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
1
Is the toner
density reference value
recorded?
Use Sim 43-01 to set the
fusing temperature
Use Sim 22-07 to set the
developer replacement cycle
counter to the specified value
Use Sim 22-06 to set the
developer counter
Use Sim 21-01 to set the
maintenance cycle to the
specified value
Use Sim 26-06 to set the
desitination specifications
Use Sim 26-13 to set the
operation mode in warm-up
Is the copy
density adjustment
value recorded?
Use Sim 46-01 to set the copy
density adjustment value
Is the vertical
copy magnification
ratio adjustment value
recorded?
Use Sim 48-01 to the
vertical copy magnification
ratio adjustment value
Is the
horizontal copy magnification
ratio adjustment value
recorded?
Use Sim 48-02 to set the
horizontal copy magnification
ratio adjustment value
Is the adjustment
value of contact pressur
between the main body resist
roller and the copy paper
recorded?
Use Sim 51-02 to set the adjustment
value of contact pressure between
the main body resist roller and the
copy paper
Make a copy and
adjust the copy
density
Make a copy and
adjust the vertical
magnification ratio
Make a copy and
adjust the horizontal
copy magnification ratio
Make a copy and adjust the
contact pressure between
the main body resist roller
and the copy paper
*1) For setting, refer to the service
memory data recoding sheet
Use Sim 25-2 to set the
toner density reference value
NO
YES
NO
YES
Are the image
lead edge position
adjustment value and
the resist roller ON
timing adjustment value
recorded?
Use Sim 50-01,50-02 to set the image
lead edge position adjustment value and
the resist roller ON timing adjustment
value
Make a copy and adjust the
image lead efge position and the
resist roller ON timing
Is the void
amount adjustmant
value recorded?
Use Sim 50-02 to set the void amount
adjustment value
End
Make a copy and adjust the
void amount
Use Sim 47 to set the AE
sensor gain is auto-matically
adj
10 – 2