SSC3088AS
30
parts from deforming.
1. Remove the screws which fix the R hinge K and the L hinge K onto
the right heat insulating plate and the left heat insulating plate re-
spectively (1 screw each).
Screw
Heat insulating
plate on the left
Screw
Heat insulating
plate on the right
2. Once the four screws at the R hinge K/the L hinge K are loosened,
open the door and insert a 0.8 mm spacer (preferably a magnet
sheet type) between the door sealer part (lower part) and the oven
front plate. Then, close the door and tighten the four screws at the
hinges.
Note: If the screws are tightened while putting the hinges fully back-
ward without clamping the spacer, there will be a gap on
the upper side of the door. Therefore, please be sure to
use the spacer.
●When tightening the screws, please gently press the handle
so that the door would not go up.
Screw for
L hinge K
Door sealer part (lower part)
Oven front plate
Enlarged photo
3. Attach the R hinge K and the L hinge K to the right and the left of
the heat insulating plate with screws (one screw each) respectively.
4. Adjust the latch. [5] Reference
[15] AC cord
1. Remove the screw (1x) which fastens the AC cord to the bottom
plate.
2. Remove the AC cord from the angle hole of the bottom plate.
3. Remove the harness which is connected to the AC cord.
Note:
Do not damage the cover of the harness at the angular hole of
the bottom plate.
[16] The D motor (intake) and the damper SW (intake)
1. How to remove the D motor (intake)
1) Remove the cabinet. [3] Reference
2) Remove the cabinet. (3 screws)
3) Remove the harness from the D motor (intake).
4) Remove the screws (2x) which fix the D motor (intake) to the
intake duct cover.
5) Pull out the D motor (intake) only while pressing the intake
damper cam with your hand so that the intake damper cam
would not come off the shutter shaft.
Note: Because it is difficult to insert the intake damper cam into the
shutter shaft again, please take care not to pull the intake
damper cam out from the shutter shaft. If it is pulled out,
please remove the intake duct top and insert it again.
2. Damper SW (intake)
1) Remove the D motor (intake) (Refer to “1. How to remove the D
motor (intake) in the above)
2) Remove the harness from the damper SW (intake).
3) Pull out the damper SW (intake) from the intake duct cover.