Analytical Balance
Instruction Manual
321-78382
Oct. 2021
Read the instruction manual thoroughly before you use the product.
Keep this instruction manual for future reference.
1
3
5
2
4
6
7
8
12
13
9
10
11
Foreword
Table of Contents
Setup
Component Names
and Functions
Display and Icons
Basic Operations
Calibration
Settings
Applications
Ionizer
Connecting and Communicating
with Peripheral Devices
Errors and Recovery
Maintenance
Specifications
Technical
Documentation
AP W Series
AP225W
AP135W
AP225WD
AP125WD
AP324W
AP224W
AP124W
AP X Series
AP324X
AP224X
AP124X
AP Y Series
AP324Y
AP224Y
AP124Y
AP W-AD Series
AP225W-AD
AP135W-AD
AP225WD-AD
AP125WD-AD
AP324W-AD
AP224W-AD
POWER
ION
ALARM

Table of Contents

Questions and Answers

  • C
    Carolyn SantanaAug 10, 2025
    What to do if the serial communication function doesn't work with a USB serial converter on Shimadzu Laboratory Equipment?
    • J
      Joshua SmithAug 10, 2025
      First, verify that the correct COM number has been set in the Windows settings. If the issue persists, the driver provided with the USB serial converter may not be set up correctly. Please refer to the Shimadzu website for details on checking/changing the COM number and setting up the driver.
  • L
    Larry PenaAug 15, 2025
    Why doesn't the serial communication function work after rebooting the PC with Shimadzu AP224W?
    • H
      Heather PerkinsAug 15, 2025
      The serial communication function cannot be used if Balance Keys has not been started up. For details on Balance Keys, refer to the Shimadzu website.
  • R
    reedrachelAug 21, 2025
    What to do if the cells are not transferred when entering data on Excel with Shimadzu AP224W Laboratory Equipment?
    • A
      angelica85Aug 21, 2025
      This issue may occur if Excel is not set to move cells after pressing the Enter key. To resolve this, in Excel, go to File > Options > Advanced Settings, and enable 'Move cell after pressing the [Enter] key.' Also, ensure that the Japanese conversion function in Windows is set to OFF, as this can interfere with data transfer.
  • D
    Daniel HullAug 28, 2025
    Why do operations sometimes seem strange with Shimadzu AP224W Laboratory Equipment?
    • J
      Jessica DennisAug 28, 2025
      Strange operations can occur if the communication speed is set too slow in Balance Keys, depending on your PC's performance. Adjust the communication speed to align with your PC's capabilities. Also, if the interval for transmitting data from the balance is too short, it can cause malfunctions. Ensure data is transmitted after it has been displayed on the screen and avoid using the continuous output function. Additionally, ensure nothing is touching the PC keyboard or mouse when data is being transmitted from the balance.
  • X
    Xavier SandersSep 3, 2025
    What to do if garbled text is loaded onto the PC from Shimadzu Laboratory Equipment?
    • L
      Laura RobertsSep 3, 2025
      If garbled text appears on your PC, the serial communication function settings on either the balance or the PC are likely incorrect. Reset these settings to resolve the issue.

Summary

Safety Precautions

Precautions on Use

Covers safety guidelines for balance usage and installation environments.

Installation and Operation Safety

Safety measures for installation work and general balance operations.

Risks in Repairs and Modifications

Warnings about hazards related to unauthorized repairs or modifications.

1 Setup

Powering On the Balance

Detailed steps for powering on the balance, including auto calibration.

4 Basic Operations

Standard Measurement Mode

Step-by-step guide for performing standard weight measurements.

Measurement Mode Settings

How to select and change the active measurement mode.

5 Calibration

Internal Weight Calibration

Performing calibration and tests using the balance's internal weights.

External Weight Calibration

Performing calibration and tests using external calibration weights.

7 Applications

Piece Counting Measurement

Detailed steps for performing piece counting measurements.

Percentage Measurement

Detailed steps for performing percent measurement.

Averaging Mode Measurement

Performing measurements to reduce fluctuations using averaging.

Solid Specific Gravity Measurement

Detailed steps for measuring the specific gravity of solid samples.

Liquid Density Measurement

Detailed steps for measuring the density of liquid samples.

Add-on Mode for Large Quantities

Using add-on mode for formulating large quantities of fine samples.

Formulation Mode Measurement

Using the formulation mode for preparing multiple samples.

Recipe Preparation for Samples

Using recipes to prepare samples, especially for compounding medicines.

Buffer Solution Preparation

Preparing buffer solutions using pre-registered recipes.

Sample Preparation for Analysis

Supporting sample collection and preparation for analysis.

Statistical Calculation

Calculating statistics like average, standard deviation from measurement data.

Comparator Function Modes

Comparing weighing values against target values and displaying status.

Pass;Fail Evaluation Mode

Judging sample weights as pass or fail against set limits.

Minimum Weighing Value Mode

Setting and evaluating the minimum weighing value for reliable measurements.

9 Connections and Communications with External Equipment

10 Errors and Recovery

Troubleshooting Guide

A guide to identifying and resolving common balance problems and error messages.

Error Message Reference

Lists potential error messages, their causes, and recovery steps.

12 Specifications

W-AD Series Specifications

Detailed technical specifications for the W-AD Series balances.

W Series Specifications

Detailed technical specifications for the W Series balances.

X Series Specifications

Detailed technical specifications for the X Series balances.

Y Series Specifications

Detailed technical specifications for the Y Series balances.

Shimadzu AP224W Specifications

General IconGeneral
Capacity220 g
Readability0.1 mg
Repeatability (Standard Deviation)0.1 mg
Linearity±0.2 mg
InterfaceRS-232C
TypeAnalytical Balance
DisplayLCD
Power SupplyAC adapter
Operating Temperature5 °C to 40 °C
Pan Sizeø80mm
CalibrationInternal calibration
Power RequirementsAC 100-240V, 50/60 Hz
Operating Humidity85 %RH or less (no condensation)