Basic Operation
Turn off the splicer. Push the release button, located on the side of the
splicer body, and remove the power supply out of the splice body.
Battery operation
Check and make sure the remaining battery capacity is 20% or greater
before operation otherwise few splices can be made.
Two ways to check remaining battery capacity
a) If battery is already inserted in the splicer, turn splicer ON. Power source
of "Battery" is automatically identified and the remaining battery
capacity is displayed on the "READY" screen.
b) Or press battery check button on the battery pack. The remaining battery
capacity is indicated on the LED indicator.
READY screen Remaining battery capacity indicator
Remaining battery
capacity display
Remaining battery
capacity indicator
Remaining battery
5 LED
80~100%
4 LED
60~80%
3 LED
40~60%
2 LED
20~40%
1 LED
Less than 10%
Do not place battery on top of AC adapter or vise-versa.
Battery can be charged while AC adapter is in power unit dock of
OFS-95 regardless of under operation or not.
CHARGE LED turns off when battery charge is completed. If CHARGE
LED flashes, replace the battery with a new one.
If battery charge does not complete in five hours or CHARGE LED does
not turn ON, the battery, AC adapter or both need replacement. Ask your