43(49)
3.5.2 Suction Box Installation
Picture 3-5: European Suction Box
When SHD is mounted on the floor stand suction box should be equipped. To
convey the dried plastic material conveniently. The installation of suction box is
simple. Install them at bottom of the hopper, point to the holes and tighten up
the screws.
Picture 3-6: Shut-off Suction Box
3.5.3 Blower Inlet Filter Installation
When dryers in the dust-contain environment or hot air requires high cleanliness,
it can option with AIF blower inlet filter.
Picture 3-7: AIF Blower Inlet Filter
Installing AIF at blower inlet port when installing it, firstly loosen screws of the
blower inlet screen , take down the screen; then install the AIF at blower inlet
port, point to the holes and tighten up the screws.