7500016 - ISTR.INSTALL. HEAT PUMP VERS. EN.docx Rev. 9 del/of 19/04/2013
Page 8-di/of 40
3. Technical specifications.
Model
BP-30WS-B BP-35WS-B BP-50WS-B BP-50HS-A BP-85HS-A BP-100HS-A BP-160HS-A
[kW] 3.0 3.5 5.0 5.0 8.5 10.5 17.0
[kW]
-
10
4.3 6.8 8.5 14.0
Absorbed power
11
[kW] 0.6 0.75 1.0 1.0 1.7 2.1 3.5
Absorbed current
12
[A] 3.0 3.8 5.5 5.5 7.9 9.8 16
Power voltage
13
[ ] 5.1 5.0 5.0 4.2 5.0 5.0 5.0
[ ]
-14
3.6 4.0 4.0 4.0
Refrigerant
- R410A
Refrigerant gas quantity
[kg] 0.65 0.75 0.85 1.60 2.85
- IPX4
Number of compressors
- Titanio
Minimum water flow
[m
3
/h] 2.5 3 3.5 4.0 6.5
Hydraulic connections
- 1
Absorbed power by fan
[W] 70 85 100 220
Fan RPM
[RPM] 830 900 850 800
Fan air flow direction
[m
3
/h] 1200 1600 2000 3400
Noise
[dB(A)] <46 50 51 53 54 60
Dimensions (L/D/H)
[mm] 660x270x470 760x270x470 955x305x565 1005x305x610 1120x430x790
[kg] 30/34 34/38 51/54 54/57 63/67 114/124
9
Variable according to ambient conditions.
10
Operating mode not included.
11
Variable according to ambient conditions.
12
Variable according to ambient conditions.
13
Single phase alternating current.
14