EasyManua.ls Logo

Shott BP-160HS-A - 3 Technical Specifications

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E N G L I S H
Nome file:
7500016 - ISTR.INSTALL. HEAT PUMP VERS. EN.docx Rev. 9 del/of 19/04/2013
Page 8-di/of 40
3. Technical specifications.
Unit of
measure
Model
BP-30WS-B BP-35WS-B BP-50WS-B BP-50HS-A BP-85HS-A BP-100HS-A BP-160HS-A
Thermal power
(heating)
9
[kW] 3.0 3.5 5.0 5.0 8.5 10.5 17.0
Refrigerant power
(cooling)
[kW]
-
10
4.3 6.8 8.5 14.0
Absorbed power
11
[kW] 0.6 0.75 1.0 1.0 1.7 2.1 3.5
Absorbed current
12
[A] 3.0 3.8 5.5 5.5 7.9 9.8 16
Power voltage
13
[V]
[Hz]
220-240
50
(Coefficient Of
Performance)
[ ] 5.1 5.0 5.0 4.2 5.0 5.0 5.0
ERR (Energy Efficient
Ratio)
[ ]
-14
3.6 4.0 4.0 4.0
Refrigerant
- R410A
Refrigerant gas quantity
[kg] 0.65 0.75 0.85 1.60 2.85
Protection grade at
water input
- IPX4
Number of compressors
- 1
Compressor type
- Rotativo
Heat exchanger
- Titanio
Minimum water flow
[m
3
/h] 2.5 3 3.5 4.0 6.5
Hydraulic connections
[mm] 50
Number of fans
- 1
Absorbed power by fan
[W] 70 85 100 220
Fan RPM
[RPM] 830 900 850 800
Fan air flow direction
Orizzontale
Fan air flow
[m
3
/h] 1200 1600 2000 3400
Noise
[dB(A)] <46 50 51 53 54 60
Dimensions (L/D/H)
[mm] 660x270x470 760x270x470 955x305x565 1005x305x610 1120x430x790
Net/gross weight
[kg] 30/34 34/38 51/54 54/57 63/67 114/124
9
Variable according to ambient conditions.
10
Operating mode not included.
11
Variable according to ambient conditions.
12
Variable according to ambient conditions.
13
Single phase alternating current.
14
Operating mode not included.

Table of Contents