Shure Incorporated
12/16
•
1.
2.
3.
•
•
1.
2.
3.
4.
Store at 3.8 V: Charges or discharges all batteries to bring them to a 3.8 volts, ideal for long term storage
Firmware
Displays the version of firmware installed on this device.
Serial Number
Displays the serial number.
Device
ID
This eight-character name is displayed when this device is detected on other network devices or in WWB software.
Press SET button to enable editing.
Use the arrow buttons to change the characters.
To finish editing, press the SET button until none of the characters are highlighted.
Storage Mode
When set to storage mode (Storage Mode = Store at 3.8 V), all batteries are charged or discharged to 3.8 volts, which is ideal
for long-term storage.
The charge status LEDs indicate the voltage state:
Red flashing = battery charging or discharging to 3.8 volts.
Amber = battery voltage at 3.8 volts.
The following indicators appear on the home screen next to each bay number:
Rdy battery at 3.8 V, ready for storage
Cold battery cold
Wrm battery warm
Hot battery hot
Err Error, press SET button for info
% percentage of charge
Charging or discharging may take several hours. The remaining time is displayed as Time to 3.8 V in the battery monitoring
menu (instead of Time to Full).
To exit storage mode:
Enter the utility menu by holding both arrow buttons.
Navigate to the Storage Mode menu and press the SET button.
Use the arrow buttons to select Off.
Press the SET button to exit.
When batteries are ready for storage, they should be removed from the charger and placed into a temperature controlled area. Recommended battery storage
temperature is 0°C (10°F) to 25°C (77°F).