5 Mounting
5.1 Commissioning requirements
Computer with Internet access to download connection diagrams in the respective
ID sensor product documentation, accessible as a PDF on the ID sensor product
page on the web (visit www.sick.com and enter the relevant product name in the
search).
Supply voltage: see "Technical data", page 21 and type label of the ID sensor to
be connected
Only perform mounting, connection, and configuration work at ambient tempera‐
tures of 0 °C to +40 °C!
Use at ambient temperatures 0 °C to –35 °C only when at rest (no mounting,
connection, or configuration work).
5.2 Mounting the connection module
Can be mounted with the cover closed.
Unobstructed access to the internal AUX male connector is required at all times in
order to access the ID sensor via RS-232 (configuration and diagnostics)
Maximum length of cable between the connection module and ID sensor when
using the serial data interfaces: 10 m
Removable cover with connection diagram can be rotated 180° and locked in
parking position
1. Hole and housing dimensions, see "Dimensional drawing", page 22, max. screw
diameter: 4 mm.
2. For installation and commissioning of the optional CMC600, refer to the CMC600
operating instructions at www.sick.com.
5 MOUNTING
12
O P E R A T I N G I N S T R U C T I O N S | CDB620 8021690/ZZN1/2021-05-07 | SICK
Subject to change without notice