The IP enclosure rating for the device is only achieved under the following conditions:
■
The cables plugged into the connections are screwed tight.
If these instructions are not complied with, the IP enclosure rating for the device is not
guaranteed!
5.2 Notes on UL approval
UL: Only for use in applications in accordance with NFPA 79. These devices shall be
protected by a 1 A fuse suitable for 30 V DC.
Adapters listed by UL with connection cables are available.
Enclosure type 1.
5.3 Connection notes
– Male connector connection: Pin assignment
– Cable: Wire color
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
Explanation of the connection terminology used in the following tables:
•
BN = brown
•
WH = white
•
BU = blue
•
BK = black
•
n.c. = not connected
•
Q = digital output
•
L+ = supply voltage (U
B
)
•
M = ground
•
L = light switching
•
D = dark switching
•
GTE6-P: PNP: load → M
•
GTE6-N: NPN: load → L+
The green LED lights up after connecting the sensor.
DC: 10 ... 30 V DC, see "Technical data", page 24
Table 1: Connections
GTE6 -P/N4xxx
-P/N6xxx
-P/N7xxx
-P/N1xxx
1 = BN + (L+) + (L+)
2 = WH n. c. -
3 = BU - (M) - (M)
4 = BK Q Q
OPERATING INSTRUCTIONS
20
O P E R A T I N G I N S T R U C T I O N S | GTE6 - Line 8015312.1KOY/2023/10/10 | SICK
Subject to change without notice