6 Commissioning
6.1 Alignment
Align the sensor with the object. Select the position so that the red emitted light beam
hits the center of the object.
You must ensure that the optical opening (front screen) of the sensor is completely
clear [see figure 3, page 21].
Figure 3: Alignment
Figure 4: Correct inclination of the sensor
6.2
Check the application conditions
Compare the sensing range and remission capability of the object with the associated
diagram (x = sensing range, y = operating reserve).
During this process, an object can only be detected in front of a background if the
remission capability of the object is significantly higher than that of the background or if
the distance between the object and the background is sufficiently long.