Emitted beam
Type of light Visible red light
Light spot size / distance 2mm x 50mm (50mm)
Electrical data
Supply voltage U
B
DC 10 ... 30 V
1)
Protection class III
2)
1)
Limit values
Reverse polarity protected U
B
connections
Residual ripple max. 5V
ss
2)
Reference voltage DC 50 V
Digital output
Output current I
max.
100 mA
Circuit protection A, B, D
1)
Response time <0.5ms
2)
Switching frequency 1kHz
3)
1)
A = U
B
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
With light / dark ratio 1:1
Mechanical data
Enclosure rating IP67
Ambient temperature, operation -25 ... +55 °C
10.2 Dimensional drawings
7.6
(0.30)
9.7
(0.38)
18.3
(0.72)
21 (0.83)
11.4
(0.45)
31.5 (1.24)
28.5 (1.12)
25.4 (1.00)
0.5 (0.02)
0.5 (0.02)
9.7
(0.38)
3 (0.12)
L D
12
(0.47)
Figure: Dimensional drawing