11.2 Mechanics/electronics
Type ICD890-x523xxxx ICD890-x434xxxx
Electrical connection Variant A connection mask:
3 female connectors, M12, 8-pin, X-coded, CAT 6A (Ethernet 1 ... 3)
1 female connector, M12, 5-pin, A-coded (FAN)
1)
1 female connector, M12, 5-pin, A-coded (CAN OUT)
1 male connector, M12, 5-pin, A-coded (CAN IN)
1 female connector, M12, 8-pin (Light 1)
1 female connector, M12, 8-pin (Light 2)
2)
1 female connector, M12, 5-pin, L-coded (PWR OUT)
1 male connector, M12, 5-pin, L-coded (PWR IN)
1 female connector, USB, 5-pin, type A
Variant B connection mask:
3 female connectors, M12, 8-pin, X-coded, CAT 6A (Ethernet 1 ... 3)
1 female connector, M12, 5-pin, A-coded (CAN OUT)
1 male connector, M12, 5-pin, A-coded (CAN IN)
1 female connector, M12, 8-pin (Light 1)
1 female connector, M12, 5-pin, L-coded (PWR OUT)
1 male connector, M12, 5-pin, L-coded (PWR IN)
1 female connector, M12, 12-pin, A-coded (I/O)
1 female connector, USB, 5-pin, type A
Supply voltage V
S
DC 24 V -10% +20%
ES1 as per EN62368-1 or SELV as per EN60950-1 (based on the currently applicable standard
respectively)
Power consumption Operation: 80 W typical
3)
, max. 100 W
4)
Standby
5)
: 50 W typical
Current consumption Max. 10 A
Housing material Cast aluminum
Housing color Light blue (RAL 5012), silver, black
Cover (rear of device) Function: For temporary access to optional storage media
Hinged
6)
, 2 fixing screws (hexagon socket, M4), captive
Recommended tightening torque: 1.5 Nm ± 0.2 Nm
Mechanical mounting 4 screws, M8 with centering pin, captive
Enclosure rating IP65 (EN 60529:1991-10/A2:2000-02 / A3:2013)
Further conditions see "Conditions for specified enclosure rating", page 7
Protection class III (according to the currently applicable EN 61140 standard)
Electrical safety EN 61010-1:2010-10
Weight Approx. 11 kg
Dimensions (L x W x H) 486.8 mm x 300 mm x 179 mm
8)
MTBF 80,000 h
9)
MTTR < 10 min
1)
For connecting the fan only.
2)
No function.
3)
At +25 °C.
4)
At +50 °C.
5)
No read cycle, ICI890 illumination unit switched off.
6)
When the cover is open, the device no longer conforms with the specified enclosure rating.
7)
Camera protection tube without protective cap inserted into the relevant opening in the ICI890 illumination unit. Camera mounted flush
onto the ICI890 illumination unit by means of 4 mounting screws.
8)
see "Device view", page 15.
9)
Continuous operation at an ambient operating temperature of +25 °C.
11 TECHNICAL DATA
36
T E C H N I C A L I N F O R M A T I O N | Camera ICD890 Generation 4 8023775/18IM/2020-07-02 | SICK
Subject to change without notice