EasyManuals Logo

SICK ICD890 User Manual

SICK ICD890
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
11.3 Performance
Type ICD890-x523xxxx ICD890-x434xxxx
Readable code struc‐
tures
1D, 2D, stacked, OCR, OCV
1D code types (bar
code types)
GS1-128 / EAN 128, UPC / GTIN / EAN, 2/5 Interleaved, Pharmacode, GS1 DataBar, Code 39, Code
128, Codabar, Code 32, Code 93, USPS (Postnet, Planet, USPS4SCB), Australia Post, Dutch KIX
Post, Royal Mail, Swedish Post
2D code types Data Matrix ECC200, GS1 Data Matrix, MaxiCode, QR code, Aztek
Stacked code types PDF417
Mounting bracket Max. 75°
1)
Conveyor speed Max. 4.5 m/s
1)
Minimum object dis‐
tance
≥ 50 mm
Number of objects per
second
≤ 10
Image output formats JPEG, TIFF, BMP, thumbnail, up to 5 FTP clients
1)
Depending on the activated functionality.
11.4 Interfaces
Type ICD890-x523xxxx ICD890-x434xxxx
USB
1)
1 USB 2.0 (service)
Ethernet GBit 3 Ethernet GBit
Ethernet 2 and 3 are connected via a switch
Function: data output (read result), image transmission, and configuration with SOPAS ET
Data transmission rate: 1 GBit/s, full duplex
Protocols: TCP/IP, FTP (real time image output)
CAN 1 CAN IN, 1 CAN OUT
Protocol: CSN (SICK CAN Sensor Network)
Function: data output (read result)
Data transmission rate: 20 kBit/s ... 500 kBit/s
Bus length depends on data transmission rate and length of cable, see "Wiring the CAN interface",
page 27
Light (depends on vari‐
ant)
Variant A connection mask:
1 Light 1, 1 Light 2
Light 1 function: communication with the illumination unit
Light 2 function: no function
Variant B connection mask:
1 Light 1
Function: communication with the illumination unit
FAN (depends on vari‐
ant)
Variant A connection mask:
1 FAN
Function: voltage supply and regulation of the device fan
I
Max
= 0.5 A
Variant B connection mask: not available, integrated fan connection available in the device
TECHNICAL DATA 11
8023775/18IM/2020-07-02 | SICK T E C H N I C A L I N F O R M A T I O N | Camera ICD890 Generation 4
37
Subject to change without notice

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK ICD890 and is the answer not in the manual?

SICK ICD890 Specifications

General IconGeneral
BrandSICK
ModelICD890
CategoryDigital Camera
LanguageEnglish

Related product manuals