EasyManua.ls Logo

SICK ICD890 - Ambient Data; Dimensional Drawing

SICK ICD890
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Type ICD890-x523xxxx ICD890-x434xxxx
I/O (depends on vari‐
ant)
Variant A connection mask: not available
Variant B connection mask:
Function: supply voltage, trigger, encoder, RS-232 data interface, 3 digital outputs
Maximum length of cable: 10 m
Maximum encoder switching frequency: 30 kHz
Maximum switching frequency for trigger: 30 kHz
Maximum switching frequency for digital output: 1 kHz
Total output currents (supply voltage, digital outputs): max 1.5 A (internal electronic fuse)
Maximum current for digital output: 0.4 A
Maximum baud rate for RS-232: 115.2 kBd (depends on cable)
Optical indicators 3 status LEDs (device status indicators)
3 double LEDs (Ethernet status indicators)
Configuration software SOPAS ET configuration software (workflow parameterization, installation wizard, diagnostic tools,
status information)
Storage media
2)
1 2.5 inch SSD (image and data logging)
1 microSD memory card (configuration data back-up)
1)
Data interface only for temporary use (service).
2)
Optional, not included with delivery.
11.5 Ambient data
Type ICD890-x523xxxx ICD890-x434xxxx
Electromagnetic com‐
patibility (EMC)
Interference: IEC 61000-6-4:2018
Immunity: EN IEC 61000-6-2:2019 (Industrial Environment)
Vibration resistance IEC 60068-2-6:2007-12
Shock resistance IEC 60068-2-27:2008-02
Ambient operating tem‐
perature
–10 °C ... +50 °C
Storage temperature –20 °C ... +70 °C
Permissible relative
humidity
Max. 95%, non-condensing
Ambient light immunity 2,000 lx on code
1)
With connected, functional fan.
11.6 Dimensional drawing
Dimensions see "Device view", page 15.
11 TECHNICAL DATA
38
T E C H N I C A L I N F O R M A T I O N | Camera ICD890 Generation 4 8023775/18IM/2020-07-02 | SICK
Subject to change without notice