EasyManua.ls Logo

SICK Inspector PIM60 series

SICK Inspector PIM60 series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CommentBinaryRangeAttributeValue tagContainer tag
figured value in the Ethernet
Result output dialog.
Only applicable for Feature type
Single edge. The chosen edge's
USINT[3, 4]POLARITY
polarity in the search direction:
3 = dark to bright, 4 = bright to
dark
a
This tag must be used inside the <POLYGON> container
b
Only available for Ethernet Raw.
c
For EtherNet/IP the position is represented as an INT value. Use the scale attribute to get more decimals
d
This tag must be used inside the <BLOB> container. The value are given for each Blob ROI (not for each found
blob)
e
This tag concerns the whole tool, i.e. not specific to the feature/edge chosen by the index
f
Red arrow points out the midpoint for the Edge count tool
g
The angle of the edge relative to the region.
h
The INTERNAL_ANGLE is the angle of a feature, i.e. the relation of the two edges of the feature.
Note
When a tool is related to the object locator and the object locator is not found in the live image
the presented results for the related tools are undefined.
8015726/ZPP7/2018-
09
©SICK AG Identification & Measuring www.sick.com All rights reserved
Subject to change without notice
48
Reference Manual
Result output formatting
Appendix
Inspector PIM

Table of Contents

Related product manuals