THR
PRO
TCH
PWR
Q
4. Press the SET pushbutton.
Setting the switch-on and switch-off delay (shift)
1. Use the plus or minus pushbutton to select tSh.
THR
PRO
TCH
PWR
Q
2. Press the SET pushbutton.
3. Use the plus or minus pushbutton to select the switch-on delay in milliseconds in
the range 1 – 500.
THR
PRO
TCH
PWR
Q
THR
PRO
TCH
PWR
Q
4. Press the SET pushbutton.
Adjusting the pulse generator
1. Use the plus or minus pushbutton to select tP.
THR
PRO
TCH
PWR
Q
2. Press the SET pushbutton.
3. Use the plus or minus pushbutton to select the duration of the pulse in millisec‐
onds in the range 1 – 500.
THR
PRO
TCH
PWR
Q
THR
PRO
TCH
PWR
Q
4. Press the SET pushbutton.
7.8.3 Adjusting the switching sensitivity
The contrast differences that have been taught are stored with a tolerance range. The
magnitude of the tolerance range can be set to one of four values (reliable, standard,
sensitive, and automated).
Measurement is more reliable when using a greater tolerance if the contrast differen‐
ces of the object vary. The sensor signals a teaching failure (Q LED flashes and “Err”
appears on the display) when tolerance ranges overlap after changing to a coarser sen‐
sitivity.
1. Press the SET pushbutton.
2. Use the plus or minus pushbutton to select Pro.
7 OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime 8020708.ZMT3/ | SICK
Subject to change without notice

Other manuals for SICK KTX Prime

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK KTX Prime and is the answer not in the manual?

SICK KTX Prime Specifications

General IconGeneral
BrandSICK
ModelKTX Prime
CategorySecurity Sensors
LanguageEnglish

Related product manuals