4. Press the SET pushbutton.
Setting the switch-on and switch-off delay (shift)
1. Use the plus or minus pushbutton to select tSh.
2. Press the SET pushbutton.
3. Use the plus or minus pushbutton to select the switch-on delay in milliseconds in
the range 1 – 500.
4. Press the SET pushbutton.
Adjusting the pulse generator
1. Use the plus or minus pushbutton to select tP.
2. Press the SET pushbutton.
3. Use the plus or minus pushbutton to select the duration of the pulse in millisec‐
onds in the range 1 – 500.
4. Press the SET pushbutton.
7.8.3 Adjusting the switching sensitivity
The contrast differences that have been taught are stored with a tolerance range. The
magnitude of the tolerance range can be set to one of four values (reliable, standard,
sensitive, and automated).
Measurement is more reliable when using a greater tolerance if the contrast differen‐
ces of the object vary. The sensor signals a teaching failure (Q LED flashes and “Err”
appears on the display) when tolerance ranges overlap after changing to a coarser sen‐
sitivity.
1. Press the SET pushbutton.
2. Use the plus or minus pushbutton to select Pro.
7 OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime 8020708.ZMT3/ | SICK
Subject to change without notice