NOTICE
Damage to the inspection window.
Reduced read performance due to scratches or streaks on the window!
■
Clean the window only when wet.
■
Use a mild cleaning agent that does not contain powder additives. Do not use
aggressive cleaning agents, such as acetone, etc.
■
Avoid any movements that could cause scratches or abrasions on the window.
■
Only use cleaning agents suitable for the screen material.
Cleaning procedure:
CAUTION
Optical radiation: LED risk group 1, visible radiation, 400 nm to 780 nm
The LEDs may pose a danger to the eyes in the event of incorrect use.
■
Do not look into the light source intentionally.
■
Do not open the housing. Opening the housing will not switch off the light source.
Opening the housing may increase the level of risk.
■
Comply with the current national regulations on photobiological security of lamps
and lamp systems.
CAUTION
Warning! Optical radiation: LED risk group 2, visible radiation, 400 nm to 780 nm
Potentially dangerous optical radiation. Can be damaging to the eyes.
■
Do not look into the light source for extended periods of time.
■
Never point the light source at people.
■
Avoid any reflections on people from reflective surfaces. Be particularly careful
during mounting and alignment work.
■
Do not open the housing. Opening the housing will not switch off the light source.
Opening the housing may increase the level of risk.
■
Comply with the current national regulations on photobiological security of lamps
and lamp systems.
If the product is operated in conjunction with external illumination systems, the risks
described here may be exceeded. This must be taken into consideration by users on a
case-by-case basis.
CAUTION
Optical radiation: Laser class 1
The accessible radiation does not pose a danger when viewed directly for up to 100
seconds. It may pose a danger to the eyes and skin in the event of incorrect use.
■
Do not open the housing. Opening the housing may increase the level of risk.
■
Current national regulations regarding laser protection must be observed.
Caution – Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
For both radiation types:
8
MAINTENANCE
60
O P E R A T I N G I N S T R U C T I O N S | Lector63x Flex C-mount and S-mount 8018071/16XD/2020-05-06 | SICK
Subject to change without notice