3 Product description
3.1 Scope of delivery
The delivery of the device includes the following components:
Table 2: Scope of delivery
No. of
units
Component Comment
1 Device in the version ordered Depending on version.
Without connecting cables and brackets.
1 Set of protective caps for electri‐
cal connections
Attached to the connections.
1 Set of warning labels in German
and French.
To replace the English version if needed.
1 Printed safety notes, multilin‐
gual
Quick guide and general safety notes
3.2 Status indicators
Four LEDs give a visual indication of the operational status and any errors that occur.
LED Color Status
Status Green Device is fully functional and the laser is switched on
(continuously lit), device is in standby mode and the
laser is switched off (flashing)
Yellow Warning
Red Device is not ready to take measurements
Possible reasons: Login via a terminal is active, device is
in error state or restarting
Ethernet Green LINK path is established (continuously lit), data trans‐
mission (flashing)
Sync Green Master: Sync signals are being sent (continuously lit)
Slave: Sync signals are being received (flashing), sync
connection is active and device synchronized (continu‐
ously lit)
In/Out Yellow Specific digital input or digital output (can be parameter‐
ized) is active
3.3 Device variants
Type Application Measuring
range
Remission
range
Connections
LMS4111R-13000 Indoor 0.7 m ... 3 m 3.5% ... 300% 3x M12
LMS4121R-13000 Indoor 0.7 m ... 3 m 2% ... 200% 3x M12
PRODUCT DESCRIPTION 3
8023198/16S6/2020-01-24 | SICK O P E R A T I N G I N S T R U C T I O N S | LMS4000
13