Operating Instructions PBS plus
OPERATING INSTRUCTIONS PBS plus 8024946 | SICK AG
Subject to change without notice
58
8. DISASSEMBLY, RETURN AND DISPOSAL
8. Disassembly, return and disposal
8.1 Disassembly
WARNING!
Bodily injury, property and environmental damage caused by hazardous measuring
materials
When coming into contact with hazardous measuring materials (e.g. oxygen, acetylene,
combustible or poisonous materials), measuring materials which are hazardous to health
(e.g. corrosive, poisonous, carcinogenic, radioactive) as well as cooling systems and
compressors, there is a risk of bodily injury as well as property and environmental damage.
In the event of faults, aggressive measuring materials at extreme temperatures and
under extreme pressure may be present on the device.
Wear necessary protective equipment.
WARNING!
Risk of burns
During removal, there is risk that hot, dangerous measuring materials will escape.
The pressure switch can heat up due to hot measuring materials.
Let the device cool sufciently before removal.
Wear necessary protective equipment.
Disassembling the device
1. De-pressurize and de-energize the pressure switch.
2. Disconnect electrical connection.
3. Remove the pressure switch via the spanner at using the socket wrench.