Operating Instructions PBS
32 ©SICKAG•Germany•Allrightsreserved•Subjecttochangewithoutnotice8013154/U275/2010/02/01
Specications Model PBS
Internaltransmissionuid
Synthetic Oil
(onlyforpressureranges<0...10barand ≤ 0 ... 25 bar abs)
Power supply L+ L+ in V DC 15 ... 35
Signal output and R
A
in Ohm 4 ... 20 mA, 3-wire R
A
≤ 0,5 k
maximum ohmic load R
A
0…10V,3-wire R
A
> 10 k
Adjustment zero point offset, max. 3 % of span
Setting time (Analogue signal) ms 3
Current consumption mA max. 100
Total current consumption mA max. 600 (max. 500 with IO-Link) incl. switching current
Switch points Individuallyadjustableviaexternalcontrolkeys
Type TransistorswitchingoutputPNPorNPN,withIO-Link:C/Q1:PNP
Number 1 or 2
Function
normallyopen/normallyclosed; windows- and hysteresis function freely
adjustable
Contact rating V DC SupplyvoltageL+-1V
Switching current mA Q1:250(withIO-Link:C/Q1:100),Q2:250
Response time ms ≤ 10
Accuracy % of span
≤
0.5 (setting accuracy)
Insulationvoltage V DC 500
Display
Design 14-Segment-LED, blue 4-digits, height 9 mm
Range Electronic 180° rotatable
Accuracy % of span ≤ 1.0 ± 1 Digit
Update ms 1000, 500, 200, 100 (adjustable)
Accuracy % of span ≤ 1.0 *
)
*
)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2)
Non-linearity % of span ≤ ± 0.5 (BFSL) according to IEC 61298-2
7. Starting, operation