EasyManuals Logo

SICK RFH630 User Manual

SICK RFH630
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
8014954/ZOZ7/2017-09-05 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com 1RFH6XX | SICK
QUICKSTART
RFH6xx
RFID read/write device (HF) with internal mid-
range antenna
RFH630
en
Intended use
The RFH630 read/write device is an intelligent SICK-
4Dpro sensor from the RFH6xx product family. It is
used for the automatic, stationary identication of
data cards and their management. The data cards are
located on moving or stationary objects. As a compact
device, the RFH630 has an integrated antenna. It
processes all standard ISO/IEC-15693-compatible
transponders on carrier frequency 13.56 MHz.
Thanks to its intelligent process logic, it can be used
either as a stand-alone solution or as part of a group
in a network.
The RFH630 read/write device sends the read results
to a higher-level computer for further processing via
its host interface. Or it receives commands for data
card management (write, read, etc.) via this interface.
Intended use also includes compliance with all infor-
mation in this Quickstart.
For simplicity in this document, the RFH630 read/
write device is referred to as the “RFH630”, unless a
clear distinction needs to be made between variants.
About this document
The purpose of this Quickstart is to allow you to
commission the RFH630 quickly and easily, and to
achieve initial read results with transponders. This
Quickstart applies to the following variants:
RFH630-1102101 (Ethernet/serial interface, exter-
nal antenna connection)
RFH630-1000001 (serial interfaces)
The Quickstart describes the commissioning process
for an application with a single RFH630.
Both device variants are used as the basis for the
examples, starting with their default settings. The op-
tional CDB620-001 connection module is used for the
industrial-standard signal distribution of the RFH630.
Supplementary and other relevant documents
The RFH630 technical information contains more
detailed information pertaining to the mechanical and
electrical installation for the (no. 8014956, German
version, PDF).
The technical information as well as additional infor-
mation, such as application examples and downloads
of associated documents and associated software,
can be found on the SICK product page on the Inter-
net at www.sick.com/RFH6xx.
- See also “Sources for obtaining additional informa-
tion” on page 5.
Information about conguration can be found in the
online help function of the SOPAS ET conguration
software.
Operating the RFH630 in a eldbus with line
topology
The optional incorporation of the RFH630 in eld-
buses is described in the relevant Operating
instructions for the CDF600-2 PROFIBUS DP, CDF600-
2 PROFINET, or CDF600 EtherCAT
®
eldbus module.
- See “Sources for obtaining additional information”
on page 5.
Safety information
This chapter concerns the safety of commissioning
personnel as well as operators of the system in
which the RFH630 is integrated.
Read this Quickstart carefully before commission-
ing the RFH630 in order to familiarize yourself
with the device and its functions. The Quickstart
is considered to be a part of the device and must
be kept in an accessible location in the immediate
vicinity of the RFH630 at all times!
The following requirements must be met if the
IP 67 enclosure rating is to be maintained during
operation (otherwise, the device will no longer meet
the conditions for any specied enclosure rating):
The side cover of the microSD card slot must
be screwed tight to the device.
The SICK cables plugged into the M12 connec-
tions (RFH630-1102101) must be screwed
tight.
Any electrical connections that are not being
used (RFH630-1102101) must be tted with
protective caps or plugs that are screwed tight
(as in the delivery condition).
Only operate the RFH630 without the cover
for a short period while inserting or removing
the memory card. During this time, protect the
device against moisture and dust.
Opening the screws of the RFH630 housing will
invalidate any warranty claims against SICK AG. For
further warranty provisions, see the General Terms
and Conditions of SICK AG, e.g., on the delivery
note of the RFH630.
Data integrity:
SICK AG uses standardized data interfaces, such
as standard IP technology, in its products. The
emphasis here is on the availability of products
and their features. SICK AG always assumes that
the integrity and condentiality of the data and
rights aected by the use of these products will be
ensured by the customer. In all cases, appropriate
security measures, such as network separation,
rewalls, virus protection, and patch management,
must be taken by the customer on the basis of the
situation in question.
Commissioning and conguration
Scope of delivery
RFH630 in the version ordered. Electrical connec-
tions tted with protective caps or plugs if neces-
sary. Without connecting cables and brackets.
Printed Quickstart: English (no. 8014954), German
(no. 8014953).
Other language versions may be available in PDF
format on the RFH630 product page on the Internet
at www.sick.com/RFH6xx.
Step 1: Mounting and alignment
Equipment required
At least 2 x M6 screws or 2 x M4 screws for mount-
ing the RFH630 on a mounting device (bracket)
provided by the customer. Screw length is depen-
dent on the mounting base (wall thickness of the
bracket). When using an optional SICK bracket, the
screws for mounting the RFH630 on the bracket
are included in the scope of delivery of the bracket.
Mounting requirements
The permissible ambient conditions for operating
the RFH630 must be observed, e.g., ambient tem-
perature, ground potential. - See “Technical data
(excerpt)” on page 4 and “Step 2: Electrical
installation” on page 2.
The device must be mounted using all 4 M6
threaded mounting holes (minimum 2) or 2 through
holes (both) provided. - See “Device layout” on
page 6.
Stable mounting device with sucient load-bearing
capacity and suitable dimensions for the RFH630.
Weight max. 760 g (not including cables). - See
“Device layout” on page 6.
The device should be as free from shock and vibra-
tion as possible when mounted.
To prevent mutual interference with a neighboring
RFH630, ensure that there is sucient distance
between the two devices which are being operated
simultaneously.
Mounting the RFH630
1. Select a suitable mounting location for the
RFH630. The mounting location and position
depend on the antenna elds of the RFH630 and
the transponders used.
2. Optional: Attach mounting kit no. 2048551
(optional accessory) to the RFH630 (see
RFH630 technical information, “Mounting”
chapter). Otherwise, mount the RFH630 on the
bracket provided by the customer using at least

Other manuals for SICK RFH630

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK RFH630 and is the answer not in the manual?

SICK RFH630 Specifications

General IconGeneral
BrandSICK
ModelRFH630
CategoryMedia Converter
LanguageEnglish

Related product manuals