The page contents show the configuration of each port for pin 2 (DI) and pin 4 (C/DI/
DO). The LEDs on the SIG200 picture will change state based on the actual state of the
connected device. The ports will reflect the IO-Link, input or output setting established
on the Configuration page. The port labels correspond to the user defined port label
names from the Configuration page. In the picture on the left side the "Power" LED is
always green to visualize that the SIG200 is powered on.
The Bus failure LED (BF) indicates if a PROFINET interface error is present.
The System failure LED (SF) indicates if a system error is present.
ACT/LINK1 + 2 indicate if there is Ethernet network connection on either port.
NOTE
Be aware that the visualization of the LEDs is not happing in real time. When starting
the SIG200 the first time the product has a initialization time after switch on of ~60 s.
7.3.3 Identification page
The identification page provides more detailed information about the connected
SIG200. This includes e.g. the product name, serial number and firmware version.
7.3.4 Configuration page
The configuration page is structured into four tabs: Gateway, Profinet Settings, IO-Link
Ports and IO-Link Devices.
On the Gateway tab you can change the Ethernet settings like the IP-address or Subnet
Mask. In addition, Profinet I&M data is shown.
The Profinet Settings define the size and structure of the Profinet process data for the
Logic Editor.
On the IO-Link Ports tab you can change the Port configuration for port S1-S4. Addition‐
ally, you can upload an IODD file from your PC and assign it to one of the SIG200 ports
(S1-S4). Therefore, the IODD-XML file and the referred device image needs to be
packed in a zip archive. This follows the same convention also used by the IO-Link Com‐
munity's IODD Finder and is the preferred way to retrieve the respective device IODDs. It
is also possible to upload the single IODD as an XML file.
7 SIG200 CONFIGURATION
46
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200 8017853/2019-06-06 | SICK
Subject to change without notice