The input and output data can be labled individually to achieve a clearer wiring in the
Logic Editor.
Figure 16: PROFINET configuration
Figure 17: Logic Editor
7.3.4.3 IO-Link ports
The IO-Link ports tab allows configuring settings of the IO-Link ports which can be used
in IO-Link or standard input/output mode.
Here, an IODD file can be uploaded to easily configure the connected IO-Link device.
Please upload first an IODD file and use the button "upload IODD" for that. Afterwards,
this IODD is stored in the repository of SIG200.
The disk usage shows how much storage capability on SIG200 is available.
After uploading the correct IODD file, it can be assigned to the port with the connected,
matching device (e. g. Port S1). This is done by selecting the IODD file on the right side
of the table via the drop down menu. All IODDs which are already in the repository will
appear and the suitable one can be selected. In case an IODD should be deleted from
the device, select the IODD to be removed and click on DELETE.