Value 2: Press the teach-in button.
2. Adjust for background without object.
Pin on RUN.
1
Schwellenwert
2
1. Wert (Objekt vorhanden)
3
2. Wert (Hintergrund ohne Objekt)
The threshold flashes and the display
reverts to the initial setting.
Sets the threshold between value 1 and 2
6.5 Auto teach-in
Pin on SET.