12.1 Dimensional drawing
15
(0.59)
26
(1.02)
61 (2.40)
max. 32
(1.26)
27
(1.06)
10
(0.39)
M5
87.5 (3.44)
4.7
(0.19)
11.8
(0.46)
30 (1.18)
65 (2.56)
1
2
8
9
14
(0.55)
6.5
(0.26)
14
(0.55)
17.5
(0.69)
7
3
4
5
6
14,4
(0.57)
9
Figure 8: Dimensional drawing
1
Alignment sight
2
LED signal strength indicator
3
Standard direction of the material being detected
4
Center of optical axis, sender
5
Center of optical axis, receiver (close range)
6
Center of optical axis, receiver (far range)
7
M5 threaded mounting hole, 6 mm deep
8
M5 threaded mounting hole, through-hole
9
M16 screw fixing and plug rotatable by 90°
13 Annex
13.1 Conformities and certificates
You can obtain declarations of conformity, certificates and the current documentation
for the product at www.sick.com. To do so, enter the product part number in the search
field (part number: see the entry in the “P/N” or “Ident. no.” field on the type label).