O P E R A T I N G I N S T R U C T I O N S
WTS26
de
en
es
fr
it
ja
pl
pt
ru
zh

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SICK WTS26P and is the answer not in the manual?

SICK WTS26P Specifications

General IconGeneral
BrandSICK
ModelWTS26P
CategoryAccessories
LanguageEnglish

Summary

About this document

Further Information Resources

Provides access to product pages, datasheets, CAD files, and other documentation.

Document Conventions and Symbols

Explains warning symbols (DANGER, WARNING, CAUTION, NOTICE) and action instruction notation.

Safety Information

General Safety Precautions

Covers essential safety guidelines for installation, operation, and environmental protection.

UL Approval Requirements

Details specific electrical supply and rating requirements for UL compliance.

Intended Product Application

Defines the sensor's intended use as an opto-electronic photoelectric proximity sensor.

Product Description

Operating and Status Indicators

Identifies and explains the function of the sensor's LEDs and control elements.

Additional Functions

Alarm Output Function

Explains the pre-failure notification output signaling sensor readiness or contamination.

Health Output Function

Describes the Health output for pre-failure notification due to contamination or cable issues.

Commissioning

Sensor Alignment Procedure

Guides on positioning the sensor to align the emitted light beam with the object.

Application Conditions

Checking Application Conditions

Details how to adjust sensing range and distance based on object remission and background suppression.

Sensing Range Setting

Teach-Turn and Potentiometer Adjustment

Explains adjusting sensing range via teach-in button or potentiometer for different models.

Specific Sensing Range Scenarios

Detecting Difficult Object Types

Provides guidance for detecting flat, glossy, contrast-rich, or uneven objects.

WTS26G for Container Detection

Highlights WTS26G's optimization for detecting containers like six-packs and single bottles.

Time Function Configuration

Setting Time Functions

Explains how to configure time-based functions, delays, and specific settings via IO-Link.

Switching Mode Configuration

Setting Light/Dark Switching

Details how to configure the sensor for light or dark switching modes.

IO-Link Data Structure

Process Data Structure Overview

Describes the byte and bit structure of process data for IO-Link communication.

Troubleshooting Guide

LED Fault Patterns and Solutions

Lists common LED fault patterns, their causes, and recommended measures for resolution.

Disposal and Environmental Handling

Sensor Disposal Procedures

Outlines country-specific regulations for disposing of the sensor and electronic waste.

Maintenance Recommendations

Regular Maintenance Tasks

Advises on regular cleaning of optical interfaces and checking connections.

Technical Specifications

Key Technical Data Summary

Presents essential technical specifications including sensing range, beam type, and electrical data.

Mechanical Dimensional Drawings

Provides detailed mechanical drawings showing sensor dimensions and connection points.

Light Spot Characteristics

Light Spot Size at Distance

Illustrates how the light spot size varies with distance for the WTS26P model.

Document Annex

Conformity and Certificate Information

Guides users on obtaining product conformity declarations and certificates from the manufacturer's website.