0
Distance in mm (inch)
Dimensions in mm (inch)
0.4
(0.02)
0.8
(0.03)
–0.8
(–0.03)
–0.4
(–0.02)
0
Recommended sensing range for
the best performance
400
(15.75)
25
(0.98)
450
(17.72)
350
(13.78)
250
(9.84)
150
(5.91)
50
(1.97)
150
(5.91)
Figure 27: Light spot diagram, Short Range
11.4 Process data structure
WTx10 A00
IO-Link V1.1
Process data 4Bytes
Byte 0: Bits 24 ... 31
Byte 1: Bits 16 ... 23
Byte 2: Bits 8 ... 15
Byte 3: Bits 0 ... 7
Bit 0/data type Q
L1
/Boolean
Bit 1/data type Q
L2
/Boolean
Bit 2/data type Q
Int1
Bit 3/data type Q
Int2
Bit 4/data type Q
Int3
Bit 5/data type Q
Int4
Bit 6/data type Sensor operation status
Bit 7 ... 15/data type [empty]
Bit 16 ... 31/data type Unsigned integer distance (whole mm)
12 Glossary
ApplicationSelect The ApplicationSelect function is available for sensors with the Multi‐
Mode function.
Selecting ApplicationSelect increases the sensing range of the sen‐
sor and the sensitivity rises so that even shiny, dark and uneven
objects, even in an inclined position, are safely detected.
OPERATING INSTRUCTIONS
66
O P E R A T I N G I N S T R U C T I O N S | WTM10L 9382969/2024-02-23 | SICK
Subject to change without notice
en